Especificaciones técnicas de luminarias led en licitaciones de alumbrado público

Especificaciones técnicas de luminarias led en licitaciones de alumbrado público

TABLA DE CONTENIDO
  1. Introducción
  2. Los estándares se refieren a las especificaciones técnicas de luminarias led
  3. Requisitos mecánicos y de carcasa
  4. Requisitos del driver LED
  5. Requisitos del chip LED
  6. Requisitos de conexiones/juntas eléctricas
  7. Requisitos de acabado (pintura)/marcado de etiquetas
  8. Requisitos de simulación de iluminación
  9. Farola certificada de ZGSM
  10. Resumen
  11. Productos Relacionados
  12. Blogs Relacionados
  13. Casos Relacionados
  14. Preguntas Frecuentes
  15. Introducción del autor

Introducción

El pliego de licitación de farolas LED es un expediente de gran importancia que estipula los requisitos técnicos y de calidad del proyecto de alumbrado público. Los proveedores y postores deben seguir estrictamente las disposiciones del documento de invitación a licitar para presentar ofertas calificadas, asegurando que la selección final de lámparas cumpla con los requisitos del proyecto y satisfaga las necesidades reales de iluminación. Los principales parámetros de las farolas LED cubren varios aspectos, incluida la estructura, los parámetros eléctricos, los chips LED, la distribución de la iluminación y la estructura de conexión, así como etiquetas y certificaciones. En este artículo, presentaremos estos parámetros uno por uno, con la esperanza de brindar una comprensión más profunda de los requisitos para las especificaciones técnicas de luminarias LED en el documento de invitación a licitar.

Los estándares se refieren a las especificaciones técnicas de luminarias led

Existen muchos estándares de la industria relacionados con las farolas LED, y diferentes regiones pueden hacer referencia a diferentes estándares debido a la influencia de diversos factores. En la región de Medio Oriente, varios estándares en diferentes áreas están más o menos involucrados debido a la influencia de diferentes fuerzas. A continuación se presentan algunos estándares comunes:

  • IESNA (Sociedad de Ingeniería de Iluminación de América del Norte): LM-79 y LM-82 para rendimiento fotométrico, LM-80 y LM-84 para vida útil de la lámpara..
  • CIE (Comisión Internacional de Iluminación): CIE ha publicado una serie de estándares internacionales sobre iluminación y óptica, como CIE 1931 y CIE 1976, que tratan sobre estándares de cromaticidad (por ejemplo, CCT, índice de reproducción cromática); CIE 007:2017 trata sobre mediciones de distribución espectral.
  • ANSI (Instituto Nacional Estadounidense de Estándares): ANSI es responsable de coordinar el desarrollo de estándares nacionales en los Estados Unidos y ha publicado muchos estándares relacionados con productos de iluminación. ANSI C136.10 es el estándar para enchufes NEMA de 3 pines y ANSI C136.41 es el estándar para bases NEMA de 7 pines.
  • IEC (Comisión Electrotécnica Internacional): IEC ha publicado muchas normas reconocidas internacionalmente relacionadas con equipos de iluminación, como la norma común IEC 60598, que cubre estándares de seguridad, rendimiento y pruebas para farolas y reflectores LED. IEC 60529 e IEC 62622 son estándares para pruebas de clasificación IP e IK.
  • ASTM (Sociedad Estadounidense de Pruebas y Materiales): ASTM ha publicado muchas normas relacionadas con pruebas de materiales y productos, como ASTM B117, que es una norma de prueba para la resistencia a la corrosión de las luminarias LED.
  • UL (Underwriters Laboratories): UL es una empresa científica de seguridad independiente que ha emitido muchas normas de certificación de seguridad para productos. Por ejemplo, UL 8750 es un estándar de prueba para chips LED y UL 1598 es un estándar de prueba para la seguridad de lámparas.

Requisitos mecánicos y de carcasa

El diseño de la carcasa y la estructura de la farola LED tiene como objetivo cumplir con los requisitos de funcionalidad y uso de la farola y al mismo tiempo garantizar su rendimiento, seguridad y durabilidad. Estos requisitos a menudo se refieren al material, peso, impermeabilización, resistencia al impacto, resistencia a la corrosión, resistencia a las vibraciones, disipación de calor, resistencia/dimensiones del soporte de instalación y material de sujeción y resistencia de la carcasa de la lámpara. A continuación se detallan algunos requisitos comunes de especificaciones técnicas de luminarias led para la vivienda y la estructura.

  • a) La luminaria debe cumplir los requisitos especificados en IEC 60598 o ANSI C.136.
  • b) La luminaria está diseñada para uso en exteriores y debe tener capacidad de iluminación direccional.
  • c) La carcasa de la luminaria debe tener compartimentos separados para el controlador y los componentes LED para garantizar un funcionamiento más frío del LED y un aislamiento eléctrico adecuado.
  • d) La carcasa deberá ser de aluminio extruido o de aluminio fundido a presión como una sola pieza. No se aceptan diseños de compartimentos LED modulares con bajo contenido de cobre y poca resistencia a la corrosión.
  • e) Los módulos de luminaria deben estar equipados con disipadores de calor de alta resistencia para garantizar una disipación de calor eficiente y evitar la acumulación de desechos.
  • f) La luminaria deberá contar con una tapa de vidrio templado liso.
  • g) La luminaria debe cumplir con la norma IK09 o superior de resistencia al impacto.
  • h) Toda la carcasa de la luminaria, incluidos los compartimentos óptico y del controlador, debe tener un grado de protección de ingreso IP66.
  • i) La luminaria debe superar la prueba de vibración según C.136.31 o normas IEC equivalentes.
  • j) El peso de la luminaria no deberá exceder los 15 kg.
  • k) El montaje de la luminaria de alumbrado público debe ser adecuado para postes con un diámetro de Ø 60-76 mm y una inserción mínima de espiga de 90 mm.
  • l) Se deberá presentar un informe de resistencia aerodinámica.
  • m) Todos los elementos de sujeción externos, como pernos, tornillos, tuercas, arandelas, resortes, etc., deben ser de acero inoxidable.
  • n) La temperatura en el punto del controlador Tcase: ≤70 ℃ @ Ta (MAX, 25 ℃) y 100% de potencia de las lámparas
  • o) Abierto sin herramientas para un fácil mantenimiento
Toolless open street light - LED street light specification
Farola abierta sin herramientas – especificación de farola LED

Requisitos del driver LED

El driver LED es muy importante, ya que actúa como el corazón de la luminaria, impulsando el correcto funcionamiento de la luz. Por lo tanto, es esencial establecer requisitos específicos para diversos parámetros de la fuente de alimentación LED, incluida la impermeabilidad, el factor de potencia (PF), la distorsión armónica total (THD), la eficacia del controlador, la vida útil (MTBF), las funciones de protección, los certificados y otros aspectos. A continuación se detallan algunos de los requisitos para el controlador LED.

Requisito general del controlador LED

  • a) El(los) controlador(es) LED de la luminaria deben ser aptos para uso exterior e integrados en el cabezal de la luminaria, permitiendo un fácil acceso para fines de mantenimiento.
  • b) El controlador LED garantiza que el módulo LED funcione correctamente suministrando el voltaje y la corriente correctos necesarios para que los LED funcionen.
  • c) Los controladores deben provenir de uno de los siguientes fabricantes: Inventronics, Philips, Osram o Mean Well.
  • d) El fabricante debe proporcionar la hoja de datos del controlador, que debe estar disponible públicamente e incluir el número de serie completo.
  • e) El controlador LED debe tener certificados que incluyan IEC62384, IEC61347-1, IEC61347-2-13
Type of LED driverCorriente constante
Protección de ingresoIP66
Corriente de salida del controlador LED≤ 1050 mA
Voltaje de entrada120 – 277 VAC , 60 Hz
Temperatura de trabajo Tcaso– 40℃ to + 80℃
Atenuación de interfaz1 – 10 V
Factor de potencia≥ 0.95 @ full luminaire load, 220VAC
Eficiencia del conductor≥ 92% @ full luminaire load, 220VAC
Distorsión armónica total THD≤ 20 % @ full luminaire load, 220VAC
La vida del conductor≥ 50K hours @ luminaire full Load, Ta (50℃)
MTBF≥ 200k hours
Estándares de seguridadUL8750, EN61347-1, EN61347-2-13, EN62384
ProteccionSCP – Short Circuit, OVP – Over Voltage, OTP – Over Temperature

Requisitos del chip LED

Los principales parámetros del chip LED incluyen flujo luminoso, eficiencia, longitud de onda de emisión, índice de reproducción cromática (CRI), corriente de funcionamiento, voltaje de funcionamiento, ángulo del haz y temperatura de color. Estos parámetros son críticos ya que influyen en el rendimiento y la aplicación del chip LED. El flujo luminoso y la eficiencia determinan el efecto de iluminación y la eficiencia energética. La longitud de onda de emisión y la temperatura del color determinan el color y la temperatura de la luz. CRI evalúa la precisión de la representación del color. La corriente y el voltaje de funcionamiento determinan si es compatible con la fuente de alimentación.

Además de estos parámetros del chip LED, el documento de licitación para farolas también tiene requisitos para las características espectrales de la luminaria, es decir, la distribución de la luz y la clasificación BUG (en Norteamérica). Estos están estrechamente relacionados con las lentes utilizadas en la luminaria. Al mismo tiempo, el material de las lentes, la vida útil del chip LED (luminaria) y la desviación del color suelen tener regulaciones específicas en el documento. A continuación se detallan algunos requisitos para chips LED y distribución de luz:

Requisitos de los chips LEDRequirements of lighting distribution and others
a) Los chips LED deben ser del tipo exterior de alta potencia fabricados por un fabricante de iluminación acreditado (Lumileds, Cree, Nichia, Osram, etc.) y deben cumplir con los estándares ANSI/NEMA/ANSLG C78.377.
b) El fabricante debe enviar y poner a disposición del público la última versión de la hoja de datos de LED, que incluye el código completo del contenedor o el número de serie.
c) La temperatura de color correlacionada (CCT) debe ser 4000 K (nominal) ± 250 K.
d) El LED debe estar dentro de las regiones de cromaticidad de 3 o 5 pasos (MacAdam Ellipse).
e) El índice de reproducción cromática (CRI_Ra) debe ser ≥70.
f) La corriente directa para el chip LED: ≤525mA
g) La eficacia luminosa del sistema: ≥120 Lm/W @ Tambient (25℃).
h) El cambio de cromaticidad (Δu’v’) para LED: ≤ 0,002 a 10 khrs, 525 mA.
a) Las luminarias deberán utilizar un reflector de aluminio de alta calidad o lentes de alta calidad (por ejemplo, PMMA) de acuerdo con el estándar UL para aumentar la salida de luz, que tienen una alta resistencia a la exposición al aire libre y a la luz ultravioleta.
b) Las lentes de las luminarias deberán ser fabricadas por un fabricante reconocido y se deberá presentar la hoja de datos especificando el número de serie completo.
c) La vida útil reportada (L70) para luminarias: ≥ 100K horas @ Tambient (25℃). d) La clasificación (BUG) para luminarias: B2 – U0 – G2 según IESNA TM-15-11.
e) La potencia de las luminarias frente a la salida de lúmenes para aplicaciones en calles deberá cumplir con los requisitos.
f) Las luminarias deben tener lúmenes del lado de la calle [FL (0 – 30) grados FM (30 – 60) grados] ≥ 75%.
g) La iluminación de la luminaria no deberá crear sombras repetidas, para lograr una visibilidad reconfortante.
h) La simulación de iluminación de las luminarias deberá cumplir con los requisitos estipulados en la sección de simulación de iluminación.

Requisitos de conexiones/juntas eléctricas

La conexión eléctrica de las farolas LED debe cumplir con los estándares de la industria, utilizando conectores de alta calidad y cables del tamaño adecuado para manejar cargas eléctricas. Al mismo tiempo, debemos asegurarnos de que las luminarias tengan una excelente capacidad de protección contra sobretensiones. Además, las farolas LED deben estar equipadas con juntas y selladores duraderos y resistentes a la intemperie para proporcionar características efectivas a prueba de agua y polvo. Todas estas medidas garantizan que las farolas LED estén protegidas de las influencias ambientales externas y garanticen su funcionamiento fiable y a largo plazo.

  • a) The luminaires must be equipped with an internal surge protection device, connected in series, with 10KV or 20KV to safeguard the electronic driver and LEDs by disconnecting the load at the end of life.
  • b) The datasheet of the surge protection device, specifying the serial number, should be provided with the latest version.
  • c) High-quality thermal cables should be utilized between the output driver and LED PCB.
  • d) The luminaires must possess a safety certificate. Safety certifications must be conducted by US Occupational Safety Health Administration (OSHA) approved Nationalized Recognized testing Laboratories (NRTL), such as CSA, ETL, TUV, UL, or other NRTL approved labs or ENEC safety.
  • e) The main power cable (3 x 1.5 mm2) should be securely fixed in the luminaire using a stainless steel gland.
  • f) The luminaires must be equipped with a 7-pins NEMA socket and shorting cap with IP66 rating, compliant with ANSI C136.41 and UL 773 standards.
  • g) The gasket will be manufacture without any joint to avoid any weak point in the sealing.
  • h) No chemical glue is to be used as that may cause breakdown of water-proof and dust-proof seal, glued junctions will be rejected.

Requisitos de acabado (pintura)/marcado de etiquetas

La etiqueta de farola LED generalmente requiere que se especifique la siguiente información: modelo de producto, marca registrada, parámetros eléctricos (potencia, voltaje, corriente, fuente de alimentación, modelo de chip LED, etc.), parámetros ópticos (CCT – temperatura de color correlacionada, CRI – Índice de reproducción cromática, espectro, etc.), certificaciones de seguridad (CE, UL, ENEC, etc.), temperatura de funcionamiento, clasificación IP (clasificación de protección de ingreso), clasificación IK (clasificación de protección contra impactos), fecha de producción y número de serie, etc. Además, el revestimiento de la superficie de la luminaria, que generalmente se especifica en los documentos de licitación, está relacionado con la resistencia a la corrosión, la resistencia a los rayos UV, la resistencia al desgaste y la durabilidad de la luminaria. Además, el color del acabado de la luminaria generalmente se especifica utilizando el código de color RAL para garantizar la coherencia entre el color del poste de iluminación y el de la luminaria. La siguiente imagen muestra la etiqueta de nuestra luminaria vial Rifle y el código de color RAL.

especificaciones técnicas de luminarias led
Label and finish – LED street light specification Etiqueta y acabado: especificación de farola LED

Requisitos de simulación de iluminación

En los capítulos anteriores, nos centramos en analizar los chips, espectros y lúmenes de LED, todos los cuales están estrechamente relacionados con las especificaciones técnicas de luminarias led. Los documentos de licitación generalmente brindan información detallada sobre las condiciones de la carretera, los requisitos de iluminación/brillo, las especificaciones de los postes de iluminación y los requisitos de potencia en vatios para el proyecto. Con base en esta información, debemos proporcionar resultados de simulación de iluminación (informe Dialux) para demostrar que nuestra especificación de alumbrado público cumple con los requisitos especificados. Para instalaciones masivas en carreteras, a veces también son necesarios proyectos prototipo (proyectos de muestra). Estos proyectos prototipo implican la verificación del rendimiento de iluminación real de las farolas para garantizar que las farolas LED funcionen como se espera en aplicaciones prácticas. Considerando la complejidad de estas tareas, no profundizaremos más en ellas aquí. Para más detalles, puede consultar las publicaciones del blog en los siguientes enlaces: diseño de alumbrado público y diseño de iluminación de Dialux EVO. La siguiente imagen muestra las condiciones de la carretera, los requisitos de iluminación y la simulación de iluminación de ZGSM.

Lighting simulation - LED street light specification
Lighting simulation – LED street light specification Simulación de iluminación: especificación de farolas LED

Farola certificada de ZGSM

ZGSM es un fabricante profesional de luces LED. Y ZGSM cuenta con varias soluciones de alumbrado público LED certificadas. A continuación enumeramos farolas certificadas UL, CE, ENEC, CB y ENEC, si está interesado puede visitar la página de diferentes farolas con certificaciones. Además de los certificados, también proporcionamos todo tipo de documentos relacionados con el alumbrado público, incluidos IP, IK, LM79, LM80, IEC62717, IEC62722, ISTMT, etc.

UL certificated street lights

UL certificated street lights

CE certificated street lights

CE certificated street lights

ENEC certificated street lights

ENEC certificated street lights

CB certificated street lights

CB certificated street lights

ENEC+ certificated street lights

ENEC+ certificated street lights

Resumen

Este artículo presenta brevemente los aspectos esenciales involucrados en los proyectos de licitación de alumbrado público LED. Estos incluyen estándares relacionados con la industria del alumbrado público LED, requisitos para la carcasa/estructura de la luminaria, controlador LED, chip LED, distribución de luz y salida de lúmenes, conexiones eléctricas y estructura de sellado, así como tratamiento y etiquetado de superficies. Comprender estos elementos nos permite evaluar rápidamente si nuestras especificaciones técnicas de luminarias LED cumplen con los requisitos establecidos en los documentos de licitación y realizar mejoras cuando sea necesario. Además, hemos adquirido conocimientos sobre certificaciones, informes y estándares relevantes relacionados con el alumbrado público LED, que son cruciales para verificar la calidad y el rendimiento del producto. Al colaborar con los laboratorios pertinentes para la verificación, podemos garantizar que nuestros productos cumplan con los estándares y requisitos. Todo este conocimiento mejora nuestra comprensión de los requisitos en los proyectos de licitación de iluminación vial, ya sea como proveedor, iniciador de proyecto o propietario. Conocer estos aspectos nos ayuda a encontrar una producción adecuada con las especificaciones técnicas de luminarias LED adecuadas. Al comprender las especificaciones requeridas en los documentos de licitación, podemos abordar mejor los desafíos y proporcionar productos de alumbrado público LED de alta calidad que cumplan con los estándares, contribuyendo a la implementación exitosa de proyectos de alumbrado público.

Productos Relacionados

Serie PV6 Inteligente Farola solar todo en dos

Series PV5 farola solar todo en uno

PV4 SOLAR STREET LIGHT

Series PV4 farola solar exterior integrada

Serie Leaf Lámpara de calle con energía solar

Serie Kmini Luminarias Solares Para Alumbrado Público Tipo Dividido

Los reflectores solares

Reflectores solares de la serie Zoom

Blogs Relacionados

Different types of street lights

Diferentes tipos de farolas y sus aplicaciones

Tagstipos de farolas
ZGSM solar street lighting system

Parámetros y Cálculos Importantes de los Sistemas de Alumbrado Público Solar

TagsSistemas de alumbrado público solar
Energy preformance contract

Contrato de rendimiento energético de la solución de alumbrado público

TagsEnergy performance contract of street lighting solution
Safety and structural requirements of street lighting

Seguridad y requisitos estructurales del alumbrado público

TagsSeguridad y requisitos estructurales del alumbrado público

Ventajas y desventajas de la energía solar y las farolas solares

TagsFarolas solares

Casos Relacionados

lámparas solares para alumbrado público en México

Series K cabezal de lámparas solares para alumbrado público en México

Series Rifle solar street lamp for country road lighting in Thailand-2

Series Rifle alumbrado solar en Tailandia

Series PV3 integrated solar street light for a farm in Malaysia

Series PV3 farola solar integrada para una granja en Malasia

Series PV solar powered parking lot lights in amusement park in Thailand

Series PV Luces de estacionamiento con energía solar en un parque de diversiones en Tailandia

Series PV2 alumbrado público solar con sensor de movimiento para iluminación de paradas de autobús en Serbia

Series PV2 alumbrado público solar con sensor de movimiento para iluminación de paradas de autobús en Serbia

Preguntas Frecuentes

  • Mejorar la seguridad del tráfico rodado.
  • Mejorar la visibilidad nocturna, reducir las actividades delictivas y mejorar la sensación de seguridad de los ciudadanos.
  • Facilite un aumento de las actividades nocturnas, mejore la eficiencia del trabajo nocturno y amplíe el horario operativo.
  • Actualmente, muchas instalaciones de alumbrado público están en proceso de actualización y sustitución. Si bien logran los propósitos 1, 2 y 3 antes mencionados, estas actualizaciones pueden reducir efectivamente el consumo de energía y disminuir los costos generales del alumbrado público.

Public lighting is a crucial service provided by local and municipal authorities. Apart from certain outdoor illumination such as plaza, parking lot, and landscape lighting, street lighting constitutes a significant portion of it. Therefore, in certain contexts or countries, “public lighting” specifically refers to street lighting.

El alumbrado público es un servicio crucial prestado por las autoridades locales y municipales. Además de cierta iluminación exterior, como plazas, estacionamientos y jardines, el alumbrado público constituye una parte importante de la misma. Por tanto, en determinados contextos o países, “alumbrado público” se refiere específicamente al alumbrado público.

ISO/IEC 17025 is a jointly issued standard by the International Organization for Standardization (ISO) and the International Electrotechnical Commission (IEC) for laboratory competence accreditation criteria. ISO 17025 certification can only be granted by authorized certification bodies. The 17025 accreditation signifies that a laboratory meets the management and technical requirements outlined in ISO 17025, aiming to ensure the accuracy, reliability, and repeatability of the laboratory’s test and calibration results. It holds international recognition and is widely applied across various sectors, including the LED industry. For instance, CB certificates issued by Chinese laboratories with ISO 17025 qualification are recognized in countries across the Middle East.

ISO/IEC 17025 es una norma emitida conjuntamente por la Organización Internacional de Normalización (ISO) y la Comisión Electrotécnica Internacional (IEC) para criterios de acreditación de competencia de laboratorio. La certificación ISO 17025 sólo puede ser otorgada por organismos de certificación autorizados. La acreditación 17025 significa que un laboratorio cumple con los requisitos técnicos y de gestión descritos en la norma ISO 17025, con el objetivo de garantizar la precisión, confiabilidad y repetibilidad de los resultados de pruebas y calibración del laboratorio. Tiene reconocimiento internacional y se aplica ampliamente en varios sectores, incluida la industria LED. Por ejemplo, los certificados CB emitidos por laboratorios chinos con calificación ISO 17025 son reconocidos en países de todo Medio Oriente.

Introducción del autor

About the author
Autor

Hola clientes,

Mi nombre es Taylor Gong, soy el gerente de producto de ZGSM Tech. Llevo más de 13 años en la industria de las luces LED. Bueno en el diseño de iluminación, la configuración del sistema de alumbrado público y el soporte de tecnología de licitación. Siéntete libre de contactarnos. Estoy feliz de ofrecerle el mejor servicio y productos.

Email: [email protected] | WhatsApp: +8615068758483

  • Mail
  • Facebook
  • Twitter
  • YouTube
  • Instagram
  • LinkedIn
  • Pinterest


Post Tags: #especificaciones técnicas de luminarias led

Ponerse en Contacto

Siempre estamos contentos con su información.
Así que no dude en ponerse en contacto con nosotros. Nos pondremos en contacto con usted lo antes posible.

Categorías

Alumbrado público
Reflector LED
Foco industrial
Luminaria para gasolinera
Luz LED Para Jardín
Farola Solar
Proyector LED
Semáforo
Luz para cultivo

¿No quiere perderse nada?

Sea el primero en recibir actualizaciones e información sobre productos y servicios.

  • Facebook
  • Twitter
  • Instagram
  • YouTube

© 2005 - 2025 · ZGSM Tech Términos de la garantía | Privacidad
Selección de idioma EN | FR | RU

  • Inicio
  • Nosotros
    • Empresa
    • Plazo De Garantía
    • Blogs
    • Noticias
    • Política de Privacidad
  • Productos
    • LED street light

      Alumbrado público

      Farola Solar

      Farola Solar

      LED reflector

      Reflectores solares

      LED foco industrial

      1000w led stadium lights

      Luz de mástil alto

      LED para gasolinera

      tunnel lights

      LED para túnel

      LED luminaria urbana

      red green yellow LED Traffic Light

      LED semáforo

      Bolardo LED

      adapters

      Accesorios

  • Solución
    • Smart Systems

      Simulation Design

      Smart Financing

  • Aplicaciones
  • Estudios de caso
  • Vídeos
  • Contacto
Search